324 Installation Guide for Clients
9 Use Open and Read.
0 = no Open and Read 1 = Open and Read on files with R (Read) and
W (Write) access 2 = Open and Read on files with R (Read), W
(Write), and X (Execute) access
The default is 2.
10 Controls network realization of MS-DOS commit calls as follows:
0 = flush dirty buffers to server and wait for server to flush buffers to
hard disk 1 = flush dirty buffers to server but do not wait 2 = flush
buffer when full or when job is done
The default is 1.
11 Control beeping while the workstation waits for a network request to be
processed. The value is set at 0 (no beeping) and cannot be changed.
12 Perform asynchronous read-ahead as follows:
0 = never perform asynchronous read-ahead 1 = perform asynchronous
read-ahead at buffer end 2 = perform asynchronous read-ahead for
second pass on a buffer
The default is 2.
13 Control three-way write, unlock, lock, and read SMB as follows:
0 = don’t issue 1 = issue
The default is 0.
14 Controls use of raw data transfer SMB protocols.
0 = don’t use 1 = use
The default is 1. Change to 0 to use Remote Access (dial-in).
15 Controls the use of hook interrupt 21 (INT21) as follows:
0 = hook INT21 1 = don’t hook INT21
The default is 0.
16–
32
Reserved