244 Installation Guide for Clients
Racal-Datacom ES3210
Required entry:
drivername = es3210$ or es3210n$
The following table summarizes the possible entries and values in the
[es3210] section of the LAN Manager PROTOCOL.INI file:
Entry Units Range Default
drivername es3210$ or
es3210n$
maxmulticasts integer 1–16 10
maxreceives integer 1–6 3
maxtransmits integer 1–50 6
slotnumber hex. 1–F See explanation
Entries in the [es3210] section of the LAN Manager PROTOCOL.INI
file have the following meanings:
drivername
Identifies the device driver name. The driver name consists of the base
portion of the filename, plus a digit if more than one adapter is
installed. The drivername is es3210$ for the first adapter, es32102$
for the second, and so on.
maxmulticasts
Specifies the number of multicast addresses that the driver supports.
maxreceives
Specifies the number of receives that can be queued simultaneously.
maxtransmits
Indicates the number of transmit chain commands that can be queued
simultaneously.
slotnumber
Specifies the number of the slot in the computer where the network
adapter resides. This entry is not necessary if there is only one
ES3210 adapter in the system. It is required if there is more than one
ES3210 adapter.