Troubleshooting Guide 8-17
8.8 When Dialing In as a Terminal, the “username” or “password:” Prompt Did Not
Display
This is considered to be a security problem.
Is the last message displayed a connect message from your modem?
YN
Did the “annex:” prompt display?
YN
Check for error messages.
Did an error message such as the following one display?
Checking authorization, please wait...
CLI authorization impossible due to error: Connection timed out.
Annex Command Line Interpreter * Copyright (C) 1988, 1996 Xylogics, Inc.
Press return to start log-in.
YN
Did an error message such as the following one display?
Checking authorization, Please wait..
Remote security server unavailable: Connection timed out
Invoking local security.
Port password:
Enter the correct port password.
Did the following message display?
Permission granted
annex:
Y N
Call Cabletron Technical Support.
Try pinging the security host IP.
Was the pinging successful?
Y N
This is like problem 8.4
Log on to the UNIX host as root. Depending on if the UNIX host supports Berkley Standard Distribution (BSD) or
System 5, enter the following:
For BSD, enter:
ps -aux|grep erpc
For System 5, enter:
ps -ef|grep erpc
A B (continue)