Chapter 9: Token Ring Problems
9-8 Troubleshooting Guide
9.6 LCD on Standalone Management Device (TRXI, Micro-T, or STHI) Indicates an
Eagle Insertion Error, Type 7
This indicates that the management device was trying to insert into the ring, but it could not because it detected a beaconing
condition.
Reset the management device.
Did the Eagle failure occur again?
YN
Isolate the management device by disconnecting its ring in/ring out connections. Let the Eagle insert onto the ring.
Did the Eagle insert into the ring?
YN
One of the stations connected to the management device is causing the problem. Isolate the management device
by disconnecting all the stations from the management device. Let the Eagle chip insert into the ring again.
Did the Eagle chip insert into the ring?
YN
Call Cabletron Technical Support.
Reconnect the cables to the ring in/ring out ports of the management device.
Is the Eagle still inserted into the ring?
YN
Call Cabletron Technical Support.
Reconnect the stations one at a time and check if the Eagle is still inserted after each station is reconnected, thus
showing that the reconnected station is operating properly.
Is the Eagle still inserted into the ring?
YN
Call Cabletron Technical Support.
Congratulations, the problem is solved.
The problem is external to this management device. Call Cabletron Technical Support.
Congratulations, the problem is solved.