Basic Problem Solving
5-6 Problem Solving
Table 5-5: Network Loading/Upline Dumping LED Patterns
Access Point Reset Button
You can force a downline load of the AP’s software from a load host and reset to
factory parameters by pressing the Reset button on the front panel of the AP during
a power-up cycle. When you press the Reset button (as the unit is powering up), the
LEDs cycle through three times to indicate that the AP recognized the reset request. If
the LEDs do not function properly after resetting the AP to its factory settings, remove
the AP, and contact your sales representative.
LEDs
1
1.
=on, =off, =steady blinking, =random blinking, =any state
1 2 3 4 5 6 7 Meaning of LED Pattern
Waiting for downline load from load host
Downline loading image from load host
Software error detected while downline
loading image from load host
TFTP file not found
Waiting for retry of TFTP load
Upgrading Flash
Flash upgrade successful
Invalid (wrong) load image
Unsuccessful Flash upgrade
Invalid load image: corrupted image
Invalid load image: image too large
TFTP error
Software error or number of retries
exceeded
Hardware error