9032563 E1 DS1 Application
3-3
DS1 Views
DS1 Configuration View
The DS1 Configuration View provides the same information as the DS1 Configuration Table
for the selected interface and allows you to modify field values.
To access: Double-click on a DS1 Configuration Table entry to access the DS1
Configuration View.
Index This field displays the index value which uniquely identifies the CSU (a
single DS1 physical interface) to which the entry is applicable.
If Index This field displays the index value uniquely identifying an interface to a
DS1.
Line Type This field displays the type of DS1 line implementing this circuit. The type of
circuit affects the number of bits per second the circuit can reasonably carry,
as well as the interpretation of the usage and error statistics. The values in
sequence describe:
Other - A line type other than those listed below.
ESF - AT&T Extended SuperFrame format DS1.
D4 - AT&T D4 format DS1. (Supported by MicroMMAC.)
E1 - CCITT recommendation G.704. (section 2.1.3.2)
E1-CRC - CCITT recommendation G.704. (section 2.1.3.1)
E1-MF - G.704 (Table 4a) with TS16 multiframing enabled.
E1-CRC-MF - G.704 (Table 4b) with TS16 multiframing enabled.
Kommentare zu diesen Handbüchern