SNMP Access Problems
6-4
Problems Accessing the Access Server
Introduction
If you experience problems with your access server responding to SNMP requests from a
network management station (NMS), verify the following:
SNMP enabled
Community name access information
Operations enabled for the community name
Network configuration
Communication to a remote NMS
Verify SNMP Enabled
To determine if SNMP is enabled on the access server, enter the following command:
Local> SHOW SNMP
SNMP State: Enabled Authentication Failure: Enabled
Community Name Address GET GETNEXT SET TRAP
PUBLIC ANY ENA ENA DIS DIS
Verify that SNMP State is Enabled. If it is not, enter the following command:
Local> CHANGE SNMP ENABLED
If this command fails, do the following:
Step Action
1 Verify that the Internet address has been set on the access server. See the section
Verify Internet Address (page 3-2).
2 Verify the access server memory usage. See the section Ver if y Access Server Memory
Usage (page 2-6).