Configuration Views Hub Redundancy Management
SPECTRUM Enterprise Manager Page64 Cabletron Ethernet Hubs
MRXI
MiniMMAC
SPECTRUM allows redundant “circuit”
connections between any two or more hub devices
that have redundant capability in their firmware.
A circuit is represented by a cable connection
from one module port on a primary hub device to
one or more module ports on secondary hub
devices. The cable connections can use any valid
cable type, including thin-net, coaxial, fiber optic,
or AUI. The terminating connectors used depend
on the type of cable connecting the module ports.
Any two or more cable connections create a
complete circular “circuit” pathway between the
two devices. One pathway is always set up as
primary and the others as secondary. The
secondary circuit becomes active if the primary
pathway fails. This allows the primary hub device
to repeat data packet information on an
alternative module port if a problem exists on the
primary port.
Although circuit connections typically occur
between devices in the same room, the circuit
connections can also occur over longer distances
between floors or buildings (with the proper FDDI
cables and associated modules). Refer to
Figure 10 (Page 65) for an illustration of a typical
redundant cable circuit connection between two
redundant hub devices.
Note:
Note:
The SIRM and the IRBM hub devices
do not have redundant circuit
compatibility available in their device
firmware.