FDDI Devices
BRIM-F6 User’s Guide Page A-9
Figure A-6. Dual Homing Topology
Concentrator 3 in Figure A-6 has redundant connections to the main ring
through either concentrator 1 or 2. The FDDI connection rules only
permit one active connection, Port B. If a cable failure severs concentrator
3’s connection to concentrator 2, CFM activates Port A.
A.6 FDDI Devices
FDDI recognizes four station configurations (SAS, DAS, DAC, and
SAC). These configurations differ by the mix of FDDI entities within the
station (see Figure A-7).
All stations must have:
one SMT
at least one MAC
one PMD
one PHY.