INSTALLATION
3-13
c. Verify that the fiber connection meets the dB loss specifications
outlined in Fiber Optic Network Requirements.
If a link still has not been established, contact Cabletron Systems
Technical Support.
3.5.5 Connecting a Thin-Net Segment to an EPIM-C
To connect a thin-net segment to an EPIM-C:
1. Set the Internal Termination Switch (see Figure 3-14), located to the
right of the port and labeled TERM to:
The on position (•) if the thin-net segment connected directly to
the port will be internally terminated at the port.
The off position (o) if the thin-net segment will not be terminated
at the port or externally terminated.
2. If the Internal Termination switch is in the On position, connect the
thin-net segment directly to the BNC port.
3. If the Internal Termination switch is in the Off position:
a. Attach a BNC tee-connector to the BNC port on the module.
b. Attach the thin-net segment to one of the female connectors on the
tee-connector.
Note: You must terminate each segment attached to the tee-connector. If
you do not attach a segment to one of the female connections on the
tee-connector, then a terminator must be placed on that connection.
c. Attach another thin-coax segment or a terminator to the other
female connector on the tee-connector.
Figure 3-14 The EPIM-C