Seite 1 - User’s Guide

MMAC-Plus™9C300-1 Environmental ModuleUser’s Guide

Seite 2

Introduction1-4 Getting Help If you need additional support related to the Environmental Module, or if you have any questions, comments or suggestion

Seite 3

2-1 Chapter 2 Installing the 9C300-1 Environmental Module Installing the 9C300-1 Environmental Module The 9C300-1 Environmental Module is installed

Seite 4 - DOC Notice

Installing the 9C300-1 Environmental Module2-2 If the MMAC-Plus chassis has not been powered up, make sure that all modules have been properly instal

Seite 5 - Contents

3-1 Chapter 3 9C300-1 Environmental Module Operation The 9C300-1 Environmental Module, as shown in Figure 3-1, performs three main functions. It moni

Seite 6

9C300-1 Environmental Module Operation3-2 External Ambient Temperature The 9C300-1 Environmental Module includes an external ambient temperature sens

Seite 7

3-3Monitoring Functions Fan Speed The 9C300-1 Environmental Module adjusts the speed of the system cooling fans (Figure 3-3) based on the external am

Seite 8 - Features

9C300-1 Environmental Module Operation3-4 System Humidity The 9C300-1 Environmental Module monitors the non-condensing humidity level of the MMAC-Plu

Seite 9 - Related Manuals

3-5Monitoring Functions LANVIEW LEDs The LANVIEW LEDs on the front of the 9C300-1 Environmental Module may be used as an aid in troubleshooting. Ther

Seite 10 - Getting Help

9C300-1 Environmental Module Operation3-6 The ALARM LED indicates the presence, or absence, of an unread system alarm(s). Unread system alarms can be

Seite 11 - Environmental Module

3-7Out-of-Band Management COM1 and COM2 Ports The 9C300-1 Environmental Module front panel has two RJ-45 communication ports for RS-232 serial commun

Seite 13 - Monitoring Functions

9C300-1 Environmental Module Operation3-8 The Ethernet™ Port Interface Module (EPIM) The 9C300-1 Environmental Module provides a port for Cabletron S

Seite 14 - External Ambient Temperature

3-9Non-Interactive Mode Non-Interactive Mode The LCD defaults to this mode if there is no user input within 60 seconds of installation of the Environ

Seite 15 - Fan Speed

9C300-1 Environmental Module Operation3-10 The Utilization Screen The Utilization Screen, as shown in Figure 3-8, is the second screen of the non-int

Seite 16

3-11Non-Interactive Mode The Power Screen The Power Screen, as shown in Figure 3-10, is the fourth screen of the non-interactive mode.Line 1 display

Seite 17 - LANVIEW LEDs

9C300-1 Environmental Module Operation3-12Interactive ModeThe LCD enters this mode upon installation. This mode allows user input through the five-fun

Seite 18 - Out-of-Band Management

3-13Interactive ModeThe Main ScreenThe Main Screen, as shown in Figure 3-13, is the initial screen of the Interactive Mode. It allows access to all of

Seite 19 - COM1 and COM2 Ports

9C300-1 Environmental Module Operation3-14Select <ACKNOWLEDGE> after reading all alarms to reset the front panel ALARM LED (red to green). Selec

Seite 20 - LCD and Keypad

3-15Interactive ModeThe Power ScreenSelect <PWR> from the System Screen, as shown in Figure 3-15, to access information about the chassis power

Seite 21 - Non-Interactive Mode

9C300-1 Environmental Module Operation3-16The Environment ScreenSelect <ENV> from the System Screen, as shown in Figure 3-15, to view environmen

Seite 22

3-17Interactive ModeThe Diagnostic Module Selection ScreenSelect <DIAGS> from the System Screen, as shown in Figure 3-15, to view the Diagnostic

Seite 23

i Notice Notice Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior

Seite 24 - Main Screen

9C300-1 Environmental Module Operation3-18The BBU ScreenSelect <BBU> from the System Screen, as shown in Figure 3-15, to view the status of the

Seite 25

3-19Interactive ModeThe Module Specific ScreenSelect a module on the Module Selection Screen, as shown in Figure 3-23, to display configuration informat

Seite 26

9C300-1 Environmental Module Operation3-20The Module Environment ScreenSelect <ENV> at the Module Specific Screen, as shown in Figure 3-24, to di

Seite 27

3-21Interactive ModeThe Module Backplane ScreenSelect <BACKPLANE> on the Module Specific Screen, as shown in Figure 3-24, to access the Module Ba

Seite 28

9C300-1 Environmental Module Operation3-22The Environmental Module Environment ScreenSelect <ENV> on the Environmental Module Specific Screen, as

Seite 29

3-23Interactive ModeThe LCD Contrast Adjustment ScreenSelect <SCREEN CONTRAST> from the Main Screen, as shown in Figure 3-13, to access the LCD

Seite 30

9C300-1 Environmental Module Operation3-24

Seite 31

4-1Chapter 4SpecificationsSafetyThe 9C300-1 Environmental Module, when properly installed in the MMAC-Plus chassis, complies with the following safety

Seite 32

Specifications4-2PhysicalDimensions12.7 H x 43.2 W x 44.5 D centimeters(5 H x 17 W x 17.5 D inches)WeightUnit: 6.5 kilograms (14 pounds)Shipping: 7.7 k

Seite 33

A-1Appendix AEPIM SpecificationsIntroductionThe 9C300-1 Environmental Module provides a port for Cabletron Systems EPIMs. EPIMs let you connect to the

Seite 34 - TEMP: xxx°F, xx°C NORM

ii Notice FCC Notice This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may no

Seite 35 - SCREEN CONTRAST ADJUSTMENT

EPIM SpecificationsA-2EPIM-F1 and EPIM-F2 The EPIM-F1 and EPIM-F2 support Multimode Fiber Optic cabling. Each EPIM has an internal Cabletron Systems FO

Seite 36

A-3EPIM-F1 and EPIM-F2Table A-2. Transmitter Power Parameter Typical ValueWorst CaseWorst Case BudgetTypical Budget50/125 µm fiber-13.0 dBm -15.0 dBm 1

Seite 37 - Specifications

EPIM SpecificationsA-4EPIM-F3The EPIM-F3 supports Single Mode Fiber Optic cabling. It has an internal Cabletron Systems FOT-F™ Fiber Optic Transceiver

Seite 38 - Environmental

A-5EPIM-F3Table A-3. EPIM-F3 SpecificationsParameter Typical Minimum MaximumTransmitter Peak Wave Length1300 nm 1270 nm 1330 nmSpectral Width 60 nm -

Seite 39 - EPIM Specifications

EPIM SpecificationsA-6EPIM-CThe EPIM-C supports thin-net coaxial cabling and is equipped with an internal Cabletron Systems TMS-3™ Transceiver. You can

Seite 40 - EPIM-F1 and EPIM-F2

A-7EPIM-A and EPIM-X (AUI Port)EPIM-A and EPIM-X (AUI Port)The EPIM-A is a DB-15 female connector used to attach segments to an external transceiver.

Seite 41

EPIM SpecificationsA-8

Seite 42

B-1Appendix BUninterruptible Power Supply (UPS)IntroductionThe MMAC-Plus can be connected to a UPS to provide an uninterruptible source of AC power. T

Seite 43

Uninterruptible Power Supply (UPS)B-2Figure B-1. Connecting EM to UPSConfiguring COM Port for UPSAfter the UPS has been connected to the COM2 port, the

Seite 44 - Grounding

B-3Verifying ConfigurationVerifying ConfigurationAfter configuring the COM port for a UPS, verify the configuration was done correctly by checking the Com

Seite 45 - EPIM-A and EPIM-X (AUI Port)

iii Contents Chapter 1 Introduction Using This Manual...

Seite 46

Uninterruptible Power Supply (UPS)B-4

Seite 47 - Connecting a UPS to an EM

Contentsiv The Diagnostic Module Selection Screen ...3-17The Diagnostic Results Screen ...

Seite 48

1-1 Chapter 1 Introduction Using This Manual Read through this manual to become familiar with its contents and to gain an understanding of the featur

Seite 49 - Monitoring UPS

Introduction1-2 Figure 1-1. The 9C300-1 Environmental Module Features System Cooling The 9C300-1 Environmental Module houses the cooling fan subsyste

Seite 50

1-3Related Manuals Environmental/Power Monitoring The 9C300-1 Environmental Module monitors and reports chassis power parameters, ambient chassis tem